- Nozzle280–310 °C (536–590 °F)
- Bed100–120 °C (212–248 °F)
- Speedup to 100 mm/s
- Dry—
- Density1.25 g/cm³
Print at 280–310 °C (536–590 °F) nozzle, 100–120 °C (212–248 °F) bed. Listed speed up to 100 mm/s.
P2S maximums: nozzle 300 °C (572 °F), bed 110 °C (230 °F).
Sources & notes
Bambu Lab P2S with Bambu Lab PPA-CF: The listed nozzle range reaches 310 °C (590 °F), above this printer's maximum of 300 °C (572 °F). This printer cannot reach the full recommended range. The low end, 280 °C (536 °F), is within that maximum.
Dataset imported 13 October 2026. Manufacturer page checked 15 October 2026.
Bambu Lab PPA-CF technical data sheet · checked 14 October 2026 · Printer source · Filament JSON
The P2S technical specifications list a hardened steel nozzle, a 300 °C maximum nozzle temperature, and a 110 °C maximum heatbed temperature.
The product page describes printing with the door closed, a shatter-safe front glass, and a chamber that seals heat. The X2D comparison labels the P2S enclosed.
The product page also says the chamber is ready at 50 °C. That is chamber air, not the heatbed maximum stored here.
Filament odometry on the specification is supported with AMS. The page does not say an AMS is in the box, and it does not name the extruder direct drive.
Questions
Can the Bambu Lab P2S reach the listed PPA-CF nozzle temperature?
The listed nozzle range reaches 310 °C (590 °F), above this printer's maximum of 300 °C (572 °F). This printer cannot reach the full recommended range. The low end, 280 °C (536 °F), is within that maximum.
Can the P2S reach the listed bed temperature?
The listed bed range reaches 120 °C (248 °F), above this printer's maximum of 110 °C (230 °F). This printer cannot reach the full recommended range. The low end, 100 °C (212 °F), is within that maximum.
Is an enclosure required?
Whether an enclosure is required is not in our current sources.
Is a hardened nozzle recorded?
This filament is recorded as needing a hardened nozzle. The stock nozzle is hardened.